The Ekdahl FAR - Command reference: Difference between revisions

From KNAS Wiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 544: Line 544:
|Runs the ''mute calibration''
|Runs the ''mute calibration''
|-
|-
|bowactuatoradd
|<s>bowactuatoradd</s>
|baa
|baa
|none
|none
Line 554: Line 554:
|Removes the ''actuator'' given in the ''parameter''
|Removes the ''actuator'' given in the ''parameter''
|-
|-
|bowactuatorset
|<s>bowactuatorset</s>
|bas
|bas
|[actuator]
|[actuator]
|Sets the ''current actuator'' to the number given in the ''parameter''
|Sets the ''current actuator'' to the number given in the ''parameter''
|-
|-
|bowactuatorload
|<s>bowactuatorload</s>
|bal
|bal
|none
|none
Line 579: Line 579:
|Returns the number of saved ''actuators''
|Returns the number of saved ''actuators''
|-
|-
|bowactuatorid
|<s>bowactuatorid</s>
|bai
|bai
|id
|id

Revision as of 16:57, 3 February 2025

Introduction

The commands in the Ekdahl FAR are using a certain naming convention to make it more clear which parts of the instrument a certain command is dealing with. Furthermore commands can be global or local, global commands change settings that will affect the entire instrument, local commands change settings depending on previously set commands. The idea of local commands is a future-proofing of the Ekdahl FAR firmware and can generally be ignored for the time being. The first part of many command-names are a prefix that denotes category, the global categories as of this writing (2025-01-26) are:

  • global* - commands that have a global reach
  • midi* - commands that deal with MIDI
  • adc* - commands that deal with the Control box and its analog-to-digital converter
  • expressionparser - commands that deal with how commands are interpreted and parsed, mainly used for debugging
  • test* - commands made for testing and debugging

The global commands as of this writing (2025-01-26) are:

Long name Short name Parameters Description
requestinfo rqi [command]:[optional parameters] Uses a command-name to retrieve rather than set information associated with it, some commands have no information associated and will return nothing. Some commands require the use of optional parameters to specify which information that is to be retrieved.
module m [module number (0)] Sets the current module. This command is intended for future versions of the Ekdahl FAR that may have more than one string module. Currently '0' is the only valid parameter
modulecount mc none Returns the number of modules in the Ekdahl FAR. Currently always returns '1'
debugprint dp [command|usb|hardware|undefined|priority|error|inforequest|expressionparser|debug]:[0|1] Used to turn on or off whether the instrument will return certain information over USB-Serial. The first parameter is the category, the second parameter is a boolean value.
version ver none Returns the current firmware version
globalsaveallparameters gsap none Saves all current data into the internal flash memory
globalloadallparameters glap none Loads all data saved into flash, effectively overwriting any changed parameters included in the last save
globalresetparameters grap none Resets all saved data in the flash memory, requires a immediate reset to be enacted
globaluservariable guv [variable number (0-9)]:[value (float)] Sets or returns the user variable defined in the first parameter, if used to set the variable, the second parameter is the value.
midiconfiguration mcf [config (0-9)] Sets or returns the current MIDI configuration
midiconfigurationadd mcfa none Adds a new MIDI configuration
midiconfigurationremove mcfr [config (0-9)] Removes the MIDI configuration denoted by the parameter passed. If there are MIDI configurations with a higher number, these are moved down the list. The current configuration may be changed during the execution of this command
midiconfigurationcount mcfc none Returns the number of MIDI configurations available
midiconfigurationname mcfn [config|name] When used as a 'set'-command, the first parameter sets the name of the current MIDI configuration. When used to retrieve information, the first parameter sets which MIDI configuration to return the name for
midieventhandler mev [noteon|noteoff|pat|cc[:0-127]|cat|pb|pc]:[command string] Used to set the command string executed when a certain MIDI event occurs. The first parameter is the type of MIDI event. With exception for the 'cc' MIDI event the second parameter is the command string. For 'cc' the second parameter is the controller number and the third parameter is the command string
midiconfigurationdefaults mcfd none Reverts all settings of the current MIDI configuration to default values and remove any added continuous controllers
midireceivechannel mrc [channel (0-16)] Sets which MIDI channel the instrument will respond to. 1-16 sets the MIDI channel while all other values sets the instrument to 'Omni' (the instrument responding to all channels)
midiallnotesoff mano [conditional (0|1)] Clears the entire MIDI buffer of notes held and turns off any bowing
adccommandmap acm [channel]:[command string] Sets the command string associated with the analog-to-digital converter channel of the Control box
adcdefaults acd none Sets all command strings associated with all analog-to-digital converter channels to their default values
adcread adcr [channel]:[return only: value] Returns the last value read by the analog-to-digital converter of the Command box on the channel given. This value is sent automatically any time a change in data is read
adcsettings adcs [channel]:[averages]:[interrupterrorthreshold]:[continuouserrorthreshold]:[continuoustimeout] Sets the settings for the averager used for the given Control box analog-to-digital channel. Averages denote number of values read and averaged, interrupterrorthreshold sets the value change required for the Control box to report a new value. The continuouserrorthreshold and continuoustimeout are used to allow for continuous changes. See the firmware for more information
expressionparserevaluate epev [expression] Evaluates the given expression and returns the calculated value. Used for debugging
testadclatency tal [value (0 - 65535)] Debugging command to test ADC latency
testadclatencyreturn talr none Stops ADC latency testing started with tal
testadcminmac tamm [channel] Debugging command to test the min/max value for a given channel

The local commands as of this writing (2025-01-26) are:

Long name Short name Parameters Description
bow bow [bow (0)] Sets the current bow. This command is intended for future versions of the Ekdahl FAR that may have more than one bow per string module. Currently '0' is the only valid parameter
bowpid bpid [conditional (0|1)] Sets whether the Proprtional-Integral-Deriviate controller is on or off. For all normal operation, the PID should be turned on. If it is turned off the instrument will not be able to play specific frequencies, but will only respond to bowmotordirectpwm-commands
bowpidki bpki [float] Sets the ki-value of the PID
bowpidkp bpkp [float] Sets the kp-value of the PID
bowpidkd bpkd [float] Sets the kd-value of the PID
bowpidintegratorerror bpie [float] Sets the minimum error value required in between the set point and the process variable for the integrator part of the PID to initiate correction
bowpidmaxerror bpme [float] Sets the maximum error correction attempted in each call to the PID loop
bowpidr bpir none Resets all data stored by the PID
bowpidpeakerror bpperr none Returns the last error value measured in between the set point and the process variable
bowcontrolfrequecy bcf [float] Sets the frequency (in Hertz) that the bowing motor should attempt to run at
bowcontrolfundamental bcu [float] Sets the fundamental frequency that all harmonics are using as its base for calculations
bowcontrolharmonic bch [float] Sets the harmonic number to use to calculate the motor speed. See bowcontrolharmonicadd and bowcontrolharmonicbase
bowcontrolharmonicadd bcha [float] Sets the number of harmonic numbers to add or remove to the value given in bowcontrolharmonic and bowcontrolharmonicbase. Can be negative values
bowcontrolharmonicbase bchb [float] Sets the harmonic number to use to calculate the motor speed but uses the value set by bowcontrolharmonicbasenote as its base. Includes any value set by bowcontrolharmonicadd and overwrites any value set by bowcontrolharmonic
bowcontrolharmonicbasenote bchbn [midi key (0-127)] Sets the MIDI key to use as the base for bowcontrolharmonicbase
bowcontrolharmonicshift bchsh [value (-32767 - 32767)] Sets how much to shift the motor speed away from the harmonic number set by bowcontrolharmonic or bowcontrolharmonicbase. The harmonic shift is dependent on the range set by bowcontrolharmonicshiftrange. Also see bowcontrolharmonicshift5
bowcontrolharmonicshiftrange bchsr [harmonics (0-36)] Sets the range of the bowcontrolharmonicshift-command. The parameter given denotes how many harmonic numbers to shift from the current harmonic number when the maximum harmonic shift has been set.
bowcontrolharmonicshift5 bchs5 [value (-32767 - 32767)] Sets how much to shift the motor speed away from the harmonic number set by bowcontrolharmonic or bowcontrolharmonicbase. Unlike bowcontrolharmonicshift this value is always calculated on a range of 5 octaves, meaning a maximum harmonic shift will equal 5 times the amount of harmonic ratios in the current harmonic table. This value is added to the harmonic shift set by bowcontrolharmonicshift
bowcontrolspeedmode bcsm [mode (0|1)] Sets the speed mode where 0 = Automatic and 1 = Manual. The only difference in between these two modes is that Automatic will automatically turn off the motor when the bow has been set in its rest position and no frequency changing commands have been sent within the time period given by bowmotortimeout
bowharmonicseries bhs [series] Sets the current harmonic series
bowharmonicseriesdata bhsl [(set only) series]:[name]:[ratios] Sets all ratios and the name of the harmonic list in the given series. There can be any number of ratio-parameters and this effectively sets the number of harmonics per octave. If required, empty harmonic lists will be added until slot is a valid number. On return, requires [series] and returns name and ratios of the harmonic series given
bowharmonicseriesratio bhsr [harmonic]:[ratio] Sets the ratio of the given harmonic number in the current harmonic series. Will increase the number of ratios in the series if needed
bowharmonicseriesratioremove bhsrr [ratio] Removes the ratio given, will move all ratios with a higher harmonic number in the series. Cannot remove all ratios
bowharmonicseriescount bhsc none Returns the number of harmonic series and their names in the format ratios:name1:name2 [etc]
bowharmonicseriessave bhss [series]:[name] Saves the current harmonic series into the slot given by the second parameter with the name give in the first parameter. Note that this command does not save it into flash memory
bowharmonicseriesremove bhsrm [series] Removes the harmonic series given in the parameter. Shifts all series' with a higher series number
bowstatus bs none Outputs debugging data. Deprecated
pickupstringfrequency psf none Returns the fundamental frequency calculated from the current audio signal if, applicable
pickupaudiopeak pap none Returns the peak amplitude of the current audio signal
pickupaudiorms par none Returns the RMS amplitude of the current audio signal
bowdebugmeasuretimetotarget bdmtt [frequency] Measure the time it takes to change from the current frequency to the target frequency, used to debug the PID
bowhome bh none Homing bow, used at startup and in case of the bow loosing position
bowcalibrateall bca none Performs all calibration routines for a single bow available in the given firmware
bowcalibratespeed bcf none Performs a bowing speed calibration
bowcalibratepressure bcp none Performs a pressure calibration
bowmotorrun bmr [(0|1)] Sets the bow motor to off or on
bowmotordirectpwm bmdp [pwm (0 - 65535)] Sets the bow motor power in 16-bit PWM values, requires that the PID is turned off
bowmotortimeout bmt [ms (0 - 65535)] Sets the bow motor shutdown timeout after bow having been put into the rest position, given in milli-seconds
bowmotorspeedmax bmsx [pwm (0 - 65535)] Sets bow motor maximum speed in 16-bit PWM
bowmotorspeedmin bmsi [pwm (0 - 65535)] Sets bow motor minimum speed in 16-bit PWM
bowmotorvoltage bmv [voltage (1.2 - 9)] Sets the bow motor voltage
bowmotorfrequency bmf none Returns the last read bow motor frequency
bowmotorcurrent bmc none Returns the last read current usage of the bowing motor
bowmotorcurrentlimit bmcl [current] Sets the current limit of the bowing motor in amperes, used to safeguard the motor, can ruin the instrument if improperly set
bowmotorpowerlimit bmpl [power] Sets the power limit of the bowing motor in watts, used to safeguard the motor, can ruin the instrument if improperly set
bowmotorfaultcommands bmfc [command string] Sets the commands to execute when a motor fault is tripped, used to safeguard the motor, can ruin the instrument if improperly set
bowmotoroverpowercommands bmopc [command string] Sets the commands to execute when the bowing motor is over the power limit, used to safeguard the motor, can ruin the instrument if improperly set
bowpressurebaseline bpb [pressure (0 - 65535)] Sets the pressure baseline value, scaled by the bowpressurepositionengage and bowpressurepositionmax parameters. The pressure baseline and pressure modifier forms the total pressure position.
bowpressuremodifier bpm [pressure (0 - 65535)] Sets the pressure modifier value, scaled by the bowpressurepositionengage and bowpressurepositionmax parameters. The pressure baseline and pressure modifier forms the total pressure position.
bowpressurerest bpr [conditional (0|1)] Puts the bow pressure in the rest position
bowpressureengage bpe [conditional (0|1)] Puts the bow pressure in the engage position
bowpressurepositionmax bppx [value (0 - 65535)] Sets the maximum hardware position of the bowing jack
bowpressurepositionengage bppe [value (0 - 65535)] Sets the engage position hardware position of the bowing jack
bowpressurepositionrest bppr [value (0 - 65535)] Sets the rest position hardware position of the bowing jack
bowpressureengagespeed bpes [speed (0 - 100)] Sets the speed of the pressure motor in RPM when going from rest to engage or vice versa. Setting this value too high will result in the pressure motor loosing track and the instrument malfunctioning as a result. Setting this value too low will result in the instrument getting increased latency and feeling sluggish.
bowpressuremodulationspeed bpms [speed (0.1 - bpes)] Sets the speed of the pressure motor in RPM when at engage and modulating the pressure. The main purpose of this setting is to avoid the bowing motor slowing down too much when modulating the pressure, resulting in audible artifacts
bowpressurehold bph [(0|1)] Sets bow hold off or on. If bow hold is on, any bowpressurerest-command will be ignored until bowpressurehold is set to off. Analog to the concept of infinite sustain
solenoid so [('0')] Sets the current solenoid. This command is intended for future versions of the Ekdahl FAR that may have more than one solenoid per string module. Currently '0' is the only valid parameter
solenoidengage se [force (0 - 65535)] Engages the current solenoid with the force given, the force is mutiplied by the force multiplier as set by solenoidforcemultiplier. The force is scaled according to the solenoidmaxforce and solenoidminforce parameters, a force of 0 always means to not engage. Also see solenoidengageduration
solenoiddisengage sd [conditional (0|1)] Disengages the solenoid
solenoidmaxforce sxf [value (0 - 65535)] Sets the maximum hardware force used
solenoidminforce sif [value (0 - 65535)] Sets the minimum hardware force used
solenoidforcemultiplier sfm [value (0 - 1)] Sets the value of the force multiplier
solenoidengageduration sed [duration (0 - 65535)] Sets the duration of the solenoid engagement in ɥS. if a value of 0 is set the solenoid will not disengage until a solenoiddisengage-command has been given. This latter behavior is not encouraged as it can ruin the instrument if improperly used
mutesetposition msp [position (0 - 65535)] Sets the mute position, scaled by the mutefullmuteposition and muterestposition
mutefullmute mfm [conditional (0|1)] Sets the mute in the full mute position
mutehalfmute mhm [conditional (0|1)] Sets the mute in the half mute position
muterest mr [conditional (0|1)] Sets the mute in the mute rest position
mutesavefull msf [conditional (0|1)] Sets the full mute position to be equal to the current mute position
mutesavehalf msh [conditional (0|1)] Sets the half mute position to be equal to the current mute position
mutesaverest msr [conditional (0|1)] Sets the mute rest position to be equal to the current mute position
mutefullmuteposition mfmp [value (0 - 65535)] Sets the full mute position to value
mutehalfmuteposition mhmp [value (0 - 65535)] Sets the half mute position to value
muterestposition mrp [value (0 - 65535)] Sets the mute rest position to value
mutesustain ms [conditional (0|1)] Sets the mute sustain to off or on. When mute sustain is on, any mutefullmute-commands sent will be ignored until mute sustain is set to off
mutebackoff mbo [backoff (0 - 65535)] Sets the mute backoff to backoff, given in mS. The mute backoff sets the time that the mute stays in the mutefullmute position before automatically going to the rest position
mutehome mh none Homing the mute
mutecalibrate mca none Runs the mute calibration
bowactuatoradd baa none Add new bow actuator
bowacutatorremove bar [actuator] Removes the actuator given in the parameter
bowactuatorset bas [actuator] Sets the current actuator to the number given in the parameter
bowactuatorload bal none Loads data from the current actuator
bowactuatorsave bas none Saves the bow pressure position rest, bow pressure position engage and bow pressure position max into the current actuator
bowactuatordata bad [actuator]:[engage]:[max]:[rest]:[id] Sets the bow pressure position engage, bow pressure position max, bow pressure position rest and actuator id of the actuator given by the first parameter
bowactuatorcount bac none Returns the number of saved actuators
bowactuatorid bai id Sets the id of the current actuator
nooperation nop none Do absolutely, positively, nothing

Please note that commands may be added or subtracted from this list as the Ekdahl FAR firmware development progresses, the most sincere attempts will be made to keep this list up to date but no guarantees will be made.