Toggle menu
Toggle preferences menu
Toggle personal menu
Not logged in
Your IP address will be publicly visible if you make any edits.

The Ekdahl FAR - Specifications: Difference between revisions

From KNAS Wiki
No edit summary
No edit summary
Line 15: Line 15:
* Weight: 500g / 8oz
* Weight: 500g / 8oz
* Max CV/Gate voltage in recommended: 12V
* Max CV/Gate voltage in recommended: 12V
* Voltage range with no attenuation: 4.096V
* Voltage range for each CV input:
** Harmonic V/Oct (ADC0) - 0-4.9V (''Harmonic'' knob turned to ''0'') / 49 Notes / ~5 octaves / 1327.716/V
** Harmonic shift (ADC1) - +/-2.425 (No attenuation)
** Pressure (ADC3), Hammer (ADC4) & Mute (ADC7) - 0-3.6V (No attenuation)
** Gate (ADC5) - 0 - 3.3V
* ADC resolution: A0-A3 @ 16-bits, A4-A7 @ 12-bits
* ADC resolution: A0-A3 @ 16-bits, A4-A7 @ 12-bits
* Input configuration: A4 and A5 configured as ''trigger''-inputs which reads new data <u>once</u> when the input voltage has passed  a certain ''threshold'', all voltages under the ''threshold'' are recorded as ''0''. All other inputs are configured as regular inputs that are continuously read and their values recorded.
* Input configuration: A4 and A5 configured as ''trigger''-inputs which reads new data <u>once</u> when the input voltage has passed  a certain ''threshold'', all voltages under the ''threshold'' are recorded as ''0''. All other inputs are configured as regular inputs that are continuously read and their values recorded.